  1. Fibaro Dimmer 2 til 374 kr og fri frakt hos Siba http://www.siba.no/data-nettbrett/smarte-hjem/fibaro-dimmer-2-127349 Sent from my SM-G920F using Tapatalk
    4 poeng
  2. Jeg fant det ut... Vet ikke helt hvorfor men saken er at av en eller annen årsak så var visuell visning slått av. Dette står det i Fibaro guiden og som løste utfordringen. ( Nå lyser ringen flott og rødt når vifta starter ) Disabling visual indicator: visual indication ring may be turned o for status signalling (turned On/OFF, power consumption). That means each status change will be signalled by a short white blink of the ring. Disabling it will not change operation of the device. To disable the LED ring: Insert the Wall Plug in a socket. Press and hold the B-button for about 3 seconds. Release the B-button after LED ring starts pulsing white. To restore visual indications perform above procedure again.
    2 poeng
  3. Flere enn meg som synes 40 USD for Netatmo-plugin er litt drøyt? Hvis dere kjører HS3 på Linux er det veldig lett å lage en gratis løsning (sikkert mulig på Windows også)! 1. Legg inn scriptet fra denne siden: https://github.com/michaelmiklis/netatmo.sh/blob/master/netatmo_nowrapper.sh Husk å legg inn brukernavn/passord nederst i scriptet. (Husk også "chmod +x Netatmo.sh") 2. "crontab -e" og sett inn dette (kjører scriptet hvert 5. min): */5 * * * * /path/to/Netatmo.sh > /usr/local/HomeSeer/html/netatmo.json 3. Installer Jon00 DataScraper-plugin 4. Jon00DataScraper.ini: [Grab8] Path=http://localhost/netatmo.json Pattern1=(?s)"Noise":(\d*), Pattern2=(?s)"Temperature":-?(\d*\.?\d*), Pattern3=(?s)"CO2":(\d*), Pattern4=(?s)"Humidity":(\d*), DeviceName1=Noise DeviceValue1=[0] DeviceText1=[0] dB DeviceName2=Temperatur DeviceValue2=[101] DeviceText2=[101] °C DeviceName3=CO2 DeviceValue3=[200] DeviceText3=[200] ppm DeviceName4=Luftfuktighet DeviceValue4=[301] DeviceText4=[301]% Den henter bare fra innedelen (jeg henter data fra utedelen via WeatherXML og WeatherUnderground), men ute.temp skal være tilgjengelig i [100] og ute-fukt i [300]. 5. Lag et event som kjører hvert 5. min: 6. Etter å ha kjørt scriptet en gang, slik at deivcene er opprettet, legg inn en passende range, osv på devicen. F.eks for temp: Og vipps, har du spart 30 USD (etter at du har sendt meg 10 USD som takk for tipset )!
    1 poeng
  4. Kan være at den ikke sender før endringen i lux verdi er så og så mye, er et parameter for det og. At f.eks om det kun er 1 lux i forskjell til hva den sendte ut sist så oppdateres den ikke, mens med 2 lux sender den ut oppdatering
    1 poeng
  5. Strømforsyning er ikke der jeg sparer penger, mye rart på markedet, men for all del, man kan være heldig/uheldig både fra Norske butikker og Ebay.
    1 poeng
  6. Den var/er i test men pga så mye ustabilitet og endringer på servicen så må jeg ta en runde på hva status er. Nå har jeg for første gang siden starten av desember klar å ha 3 dager på rad uten problemer med appen dems. Så håper de er ferdige med hva enn de har drevet med den siste tiden. Om tiden strekker til skal jeg se hva jeg får til løpet av helga.
    1 poeng
  7. Tenkte jeg skulle forsøke meg på å få kontakt med MyQ. Jada, vet at det finnes en plugin til dette allerede, men fant ut at dette kunne være en artig og relativt enkel plass å begynne å se på scripting. Jeg fant først en side på nettet som kan hjelpe til med å lage de klassene man trenger, dette skal visstnok også kunne implementeres rett inn i Visual Studio, men jeg gikk på jsonutils.com. Her kan du lime inn json strengen, eller en URL, så får du ut klassene. Status kan ha fire statuser : 1 - åpen 2 - lukket 3 - closing 4 - opening Koden min ble da som følger : Class Min_lille_lekestue Public Class Attribute Public Property AttributeId As Integer Public Property Name As String Public Property Value As String Public Property UpdatedTime As String Public Property MyQDeviceTypeAttributeId As Integer Public Property IsDeviceProperty As Boolean Public Property AttributeDisplayName As String Public Property IsPersistent As Boolean Public Property IsTimeSeries As Boolean Public Property IsGlobal As Boolean Public Property UpdatedDate As DateTime End Class Public Class Device Public Property MyQDeviceId As Integer Public Property MyQDeviceTypeId As Integer Public Property MyQDeviceTypeName As String Public Property DeviceId As String Public Property DeviceName As String Public Property TypeId As Integer Public Property TypeName As String Public Property RegistrationDateTime As DateTime Public Property SerialNumber As String Public Property UserName As String Public Property UserConnectServerId As Integer Public Property UserCountryId As Integer Public Property Attributes As Attribute() Public Property ChildrenMyQDeviceIds As String Public Property UpdatedBy As String Public Property UpdatedDate As DateTime Public Property ParentMyQDeviceId As Integer? End Class Public Class JsonKlasse Public Property Devices As Device() Public Property ReturnCode As String Public Property ErrorMessage As String Public Property CorrelationId As String End Class Public Sub Main(ByVal Params As Object) Dim Attrib As New Attribute Dim Token As String Dim objToken As New JObject Dim TokenUrl As String Dim Tokenjson As String Dim TokenwebAddress As String Dim StatusUrl As String Dim Statusjson As String Dim objStatus As New JsonKlasse Dim Status As String Dim StatuswebAddress As String Dim appId As String Dim username As String Dim password As String 'Some Constants appId = "Vj8pQggXLhLy0WHahglCD4N1nAkkXQtGYpq2HrHD7H1nvmbT55KqtN6RSF4ILB%2fi" username = "**account_name**" password = "**account_password**" TokenwebAddress = "https://myqexternal.myqdevice.com/Membership/ValidateUserWithCulture?appId=" StatuswebAddress = "https://myqexternal.myqdevice.com/api/UserDeviceDetails?" 'Get Token - gets the token from the Myq device, this will change expires after about an hour TokenUrl = TokenwebAddress & appId & "&securityToken=null&username=" & username & "&password=" & password & "&culture=en" Tokenjson = hs.URLAction(TokenUrl, "GET", "", "") objToken = CType(JsonConvert.DeserializeObject(Tokenjson), JObject) Token = objToken.Item("SecurityToken").ToString() 'Get Status - getting the status json and deserealise it to a string, prints the status in immediate window of VS and the HS log StatusUrl = StatuswebAddress & "appId=" & appId & "&securityToken=" & Token Statusjson = hs.URLAction(StatusUrl, "GET", "", "") objStatus = JsonConvert.DeserializeObject(Of JsonKlasse)(Statusjson) Status = objStatus.Devices(1).Attributes(3).Value If Status = 2 Then hs.Writelog ("Garasjeporten er lukket") Debug.Print("Garasjen er lukket" & Status) End If End Sub End Class
    1 poeng
  8. Det eneste som er spes. med dette at enheten kan ikke sette opp sitt eget nettverk. Dvs. trenger alltid en eller annen "Central Controller".
    1 poeng
  9. Fikk løst det med å deseralisere til klasser.
    1 poeng
  10. Kom over denne linken for litt siden: https://stickerapp.no/
    1 poeng
  11. Dette vil gjøre omtrent det du vil. Her har man 2 triggere: 1. Når klokka blir nøyaktig 06:45:00 så sjekker den hva lux-verdien er og slår på lyset hvis den er under 50 lux. 2. Når lux-verdien kommer under 50 lux, så sjekker den om klokka er mer enn 06:45 og slår i så fall på lyset. Jeg ville nok heller gått for at lyset slår seg på ved neste polling etter kl 0645 (eller endre det til 0630, da vil jo lyset slå seg på senest 0645 hvis lux er under 50).
    1 poeng
  12. det blir som regel benyttet hvis skapet er plassert nært badet og det ikke er plass til noe annet, men hvis badet skal bygges fra bunnen av (evt veggene skal åpnes), er det en fordel å putte den inn på badet sammen med resten av bryterene. om veggen er åpen, kan jeg anbefale Elko sin Big Box siden du da får god plass til eventuelle moduler. si ifra til elektrikeren din at du vil ha det på en eller flere av lysbryterene. det er ihvertfall normalt at den også har 2-polet brudd, men jeg har ikke nek-en foran meg så jeg får ikke sitert den. eller legge en fjær bak 2-pol bryteren, slik at man må ta av vippen for å få skrudd av bryteren. kanskje ikke helt etter boka, men det får da jobben gjort. stemmer uansett er praksis at om det er bad, så settes det inn en 2-polbryter, da er man uansett sikret. det er ikke problem å gjøre slik som jeg har det, en 2-pol på toppen, som funker som hovedbryter, og 2 mikromoduler med 1-pol brudd etter den. vifta jeg har. har fuktsensor, så den har jeg ikke giddet å koste på modul til. men har man en "dum" vifte, kan det sikkert være praktisk å ha styring på.
    1 poeng
  13. Det var bare gladmeldinger ute å vanket i dag. Telldus-appen er godkjent og kan nå finnes i Z-Way sin online App-store rett i brukergrensesnittet. I tillegg vant jeg visst her på Forumet 18. Januar
    1 poeng
  14. Så da må jeg bare finne meg 3-4 timer ledig tid til å konfigurere den...
    1 poeng
  15. You word is my command :-) Tok meg mer en en time første gang for å si det slik. {"deviceAccountId":"XXXdinedataXXX","deviceAddress":null,"deviceAddressModel":{"city":"Oslo","countryCode":"NO","county":"Oslo","district":"Oslo","houseNumber":null,"label":"Mollergata, Oslo, 0179, Norway","postalCode":"0179","state":"Oslo","street":"Mollergata Ave"},"deviceSerialNumber":"XXXdinedataXXX","deviceType":"XXXdinedataXXX","firstRunCompleted":true,"notificationEarconEnabled":true,"postalCode":"0179","responseStyle":"CONCISE","searchCustomerId":"XXXdinedataXXX","temperatureScale":"CELSIUS","timeZoneId":"Europe/Oslo","voiceCastEnabled":null,"autocastToThisClient":false,"isSaveInFlight":true}
    1 poeng
  16. Kom over denne: https://sites.google.com/site/moosyresearch/projects/samsung_shape
    1 poeng
  17. 1 poeng
  18. Dette skyldes at det er blitt logget en htnl tag som ikke HS liker. Jeg er på saken for å fine ut av det skyldes. Når det gjelder restart ved timeout er det en svakhet om verisure er nede over lengere periode - siden pluginen da vil restarte seg konstant. Dette skal jeg også få sett på. 2.4 var en den største oppdateringen, og da sniker det seg alltid inn noen feil uansett hvor mye man tester. Jeg prioritere kveldene mine nå til å komme med 2.5 som retter de feilene som er funnet i 2.4 Om du sender meg log filen din når den er blank så kan jeg se hva som er logget og dermed hva som er feil.
    1 poeng