Fejl ved binære parametre.
Hvis angives som nedenfor, hvor bit#1 er udeladt, da den ikke bruges, så vises de øvrige bit forkert.
<Parameter name="33" group="30" access="rw" type="binarycheck">
<Setting values="2,4,8,16,32" default="0" size="1" />
<Title>Non-secure commands for AG in logical device 1.</Title>
<Description>Specifies that commands to devices in the association groups for logical device 1 is sent non-secure. This parameter is only relevant if ZHC5010 is included secure. See chapter regarding ZHC5010 included secure.
0 - No commands are sent non-secure.
0x01 Not used.
0x02 Basic Report is sent non-secure.
0x04 Basic Set is sent non-secure.
0x08 Binary Switch Set is sent non-secure.
0x10 Binary Toggle Switch Set is sent non-secure.
0x20 Multilevel Switch commands are sent non-secure.
</Description>
</Parameter>
<Parameter name="34" group="30" access="rw" type="binarycheck">
<Setting values="1,2,4,8,16,32" default="0" size="1" />
<Title>Non-secure commands for AG in logical device 2.</Title>
Vises sådan:
Paramter #34 har bit et valg også.