Gå til innhold
  • Bli medlem
Støtt hjemmeautomasjon.no!

Søk i nettsamfunnet

Viser resultater for emneknaggene 'aeotec'.

  • Søk etter emneknagger

    Skriv inn nøkkelord separert med kommaer.
  • Søk etter forfatter

Innholdstype


Kategorier

  • Generelt
    • Automasjonskaféen
    • Annen Elektronikk
    • Ditt system
    • Grafikk og design
    • Nettverk
    • Nybegynner
  • Leverandører
    • ELKO Smart
    • HeatIt
    • Namron
  • Bruksområder
    • A/V-kontroll
    • Belysning
    • Klimakontroll
    • Overvåking
    • Sikkerhet
    • Strømsparing og strøm-overvåkning
    • Talestyring
  • Systemer
    • Fibaro Home Center
    • Futurehome
    • Home Assistant
    • HomeKit
    • HomeSeer
    • Homey
    • Node-Red
    • openHAB
    • SmartThings
    • Øvrige systemer
  • Teknologi / Protokoller
    • Blåtann
    • irDA
    • KNX
    • Matter
    • Mikrokontrollere
    • MQTT
    • RF
    • xComfort
    • Z-Wave
    • ZigBee
  • Utlån, kjøp og salg
    • Prisjakt
    • Kjøp / Salg
    • Powerbuy
    • Kommersielle tilbud
    • Utlån
  • Nettstedet
    • Kunngjøringer
    • Nyheter
    • Ris, ros og spørsmål om forumet

Blogger

  • En teknologisk hverdag
  • Enda en hobby?
  • Smånytt
  • en guide til elektro-verdenen

Kategorier

  • Nyheter
    • Produkter
    • Programvare
  • Tester
    • Systemer
  • Guider
    • Fibaro
    • HomeSeer
    • Nettverk
    • openHAB
    • Z-Wave
    • ESP32

Finn resultater i...

Finn resultater som inneholder...


Startdato

  • Start

    Slutt


Sist oppdatert

  • Start

    Slutt


Filtrer etter antall...

Ble med

  • Start

    Slutt


Gruppe


System

Fant 25 resultater

  1. Olex

    Aeotec multisensor 7

    Er det noen her som har fått denne til å virke 100% mot homeseer? Eg har to MS7 som ikke kan brukes som givere for varmestyring. Problemet er at selv om eg setter threshold for temperatur til eksempelvis 0,5 grader, vil den ikke rapportere temperaturendringer på 0,5 grader eller mer, den sender uansett kun standard rapport en gang i timen. Det rare er at selv om threshold for lysstyrke er satt til standard på 250 lux, rapporterer den alle endringer, selv 1 lux er nok til å rapportere endring i lys. Tanken slår meg at det er noe feil i hvor data havner i registeret til MS7. Har testet både på batteri og USB strøm, reset til factory default mange ganger, fjernet/lagt til "non secure" like mange ganger. Har mange MS6 sensorer, de kjører på USB strøm og jeg er strålende fornøyd med de. Har rapportert dette til Aeotec den 29.november i fjor, fortsatt ikke løst. Har fått tilsendt 2 FW oppdateringer som eg har testet, men ingen forskjell. Med den siste versjonen, skriver Aeotec at "This has a few S2 issues but unsecure looked pretty good". Har ikke hørt i fra de på 14 dager, så eg regner med at dette ikke blir løst med det første. Hvis ikke noen andre har positive erfaringer med MS7 mot HS, vil eg nesten fraråde noen til å kjøpe disse for tiden. Bevegelsessensor funksjonen virker fint, men rapportering av temperatur/lysstyrke fungerer ikke, i hvert fall med mine to. (Det var opprinnelig tre, men den ene ble returnert da den ikke virket i det hele tatt). Ole
  2. Jeg skal koble opp en Multisensor 6 i taket og har grublet litt på strøm til den. Jeg har 230V tilførsel til en spotkasse som jeg tenkte dette skulle monteres i. Jeg fikk litt tips tidligere og Heatit sin transformator ned til 5V virker som en grei løsning, men jeg er litt usikker på koblingen på 5 pin på USB. koblingsskjema for trafo viser at mellom lasten skal det gå kanel fra 5V og til 0V. På USB terminalen er det fem tilkoblingspunkt. S, +, D-, D+, og -. Jeg har koblet 5V mot + og 0V mot -, men jeg vet ikke helt om det er riktig. Kan noen hjelpe med dette?
  3. Hei, ny bruker her. Jeg planlegger et nytt hjemmeautomasjons-system som skal forsøke å styre last til oppvarming, vha Home Assistant(på en Pi4) og Tibber. Så langt går jeg for å standardisere på zigbee, men det eneste punktet der jeg ikke finner et godt zigbee-alternativ på er switch til varmtvannsbereder. Der ser det ut som om det Aoetc Heavy Duty 40 A som er anbefalingen, og den bruker z-wave. Det er klart, jeg kan kjøpe en z-wave dongle og kjøre både zigbee og z-wave, men finnes det et zigbee alternativ for meg?
  4. Aeotec Heavy Duty Smart Switch Gen5 Z-Wave | FINN torget
  5. Jeg skal pusse opp en stue og skal muligens rive alt av tak og vegger. I den forbindelse vil jeg legge opp strøm til en sensor som kan brukes med Home Assistant senere. Tidligere mener jeg alle sverget til Multisensor 6 så da lurte jeg på er det denne, eller 7, som fremdeles er det beste på markedet? Jeg er ennå i stuss på om jeg skal montere den i taket eller under eksisterende brytere på veggen. Har noen erfaringer her?
  6. Har utfordringer med at ID Locken min går i "sovemodus" etter kort tid etter direkte betjening. Dette gjør at noden oppfattes som død og kan ikke betjenes fra Home Assistant. Etter direkte betjening av ID Lock - Altså trykke på tastaturet, låseknappen på innsiden eller åpne døren, så våkner den til liv igjen, og låsen kan betjenes fra HA i en liten stund, før den dør igjen. Kjører HA på Raspberry Pi 4 med Aeotec gen 7 USB stick med ID Lock Z-wave modul. Home Assistant OS med Z-wave JS integrasjon. Andre som opplever det samme, og /eller vet om det går an å sette ID Locken i standby og ikke sleep, slik at den alltid holder liv i Z-waven? Eventuelt om dette er en bug? Synes det er merkelig at ID Locken må "aktiveres" for å holde liv i Z-wave kommunikasjonen... Miste litt av hensikten med fjernstyring
  7. Hei. Jeg driver å lager en liste over enheter jeg ønsker, og hvilken leverandør og modell jeg vil gå for. Jeg er rimelig bestemt på z-wave, så tenkte nå å nevne her hva jeg tenker, og lurte på om andre her eventuelt har kommentarer til det jeg velger eller anbefalinger til annet utstyr. Smarte lysbrytere: Heatit Z-dim (muligens z-dim 2 som kommer snart, men må lanseres fort nok da jeg bygger nå) Smarte termostater: Heatit Z-TRM3 + Z-Water Smarte bevegelsessensorer: Aeotec trisensor eller multisensor 6 (eller 7, avhengig av tilgjengelighet / pris) Smarte dør-/vindusensorer: Sensative strips Smarte stikkontakter: Aeotec elller fibaro relay der det er nyttig Smart garasjedør: Aeotec eller fibaro relay Smart markisekontroll: Aeotec eller Fibaro relay Smart dørlås: id lock 150 Smart ringeklokke: (ikke kommet så langt, finnes dette under z-wave?)
  8. Bruker denne fra Aeotec og Heatit Zwave termostater,det funker finfint med openhab på rp3 https://www.kjell.com/no/produkter/smarte-hjem/kontroller/aeotec-z-stick-gen5-usb-adapter-p50549 Vil den funke sammen med Fibaro smartplugger? https://www.kjell.com//no/produkter/smarte-hjem/smarte-hjem-losninger/fibaro-smarte-hjem/fibaro-z-wave-fjernstrombryter-med-energimaler-p50884
  9. Hei! Ny bruker her på forumet. Mye lærerikt å lese, men jeg er fortsatt ikke sikker på hvilken hardware jeg skal velge i mitt neste steg. Hadde derfor satt stor pris på forslag og kommentarer. Først litt om dagens oppsett: Eldre hus med Tibber m. Pulse, Tesla integrasjon, flere Sensibo og Philips Hue devicer ++ Målet er å samle mest mulig i Tibber, bruke mer varmestyring ("Aeotec - Heavy Duty Switch" (for varmtvannstanken) og "Heatit Z-TRM3" (for gulv)) - for å på den måten få mer kontroll på energibruken samtidig som det selvfølgelig er gøy og nerdete. For å komme dit må jeg selvfølgelig ha hjelp fra elektriker - men før det vil jeg lande på system og kjøpe inn utstyret. Her kommer til slutt det jeg spør etter: Hvilket system er mest fremtidsrettet og har den støtten jeg trenger for å integrere med Tibber? Min foreløpige konklusjon er Homey - eller Homey Pro. Hvilken smart dimmer er rimelig og god nok når man skal bytte ut gamle ELKO 315GLE? Homey skal i tilfelle plasseres i etg. 2 mens dimmere brukes i etg. 1 og 3. Hva tenker dere om denne dimmeren: https://www.proshop.no/Smarthus/Jumitech-Zigbee-Dimmer/2938989 Hvilken trådløs bryter bør jeg velge? Ser ut som de koster mer enn selve dimmeren. På forhånd tusen takk for eventuelle svar!
  10. Hei alle sammen, jeg kjører i dag ett lite Z-Wave nettverk på hytta der jeg har en Heatit TF016 med FW1.8 som fungerer helt som jeg ønsker, har også noen Fibaro Motion Sensor som fungerer fint. Jeg hadde på dette tidspunktet en Z-Wave Razberry GIPO kort på Pi3. Kjøpte rett etter jul en ny Z-Wave Z-TRM3 Fw4.0 som jeg skulle legge til nettverket, noe som viste seg å være vanskelig og etter en del googling ser jeg at jeg ikke var alene om det. Kjører i dag Pi3 med Aeotec USB Z-Stick Gen5 og helt nyinstallert HA og har satt opp Z-Wave JS, jeg har fått lagt til alle enhetene i nettet mitt på nytt. Problemet i dag er at rekkevidden på den nye Z-TRM3 termostaten er helt elendig, jeg får ikke kontakt med den uten at GW står på samme rom som termostaten, gjør de det så fungerer alt som en drøm (får endret target temperatur også). Men jeg ønsker ikke at GW skal ligge inne på badet, der jeg ønsker å ha den er ca 5 meter unna og jeg har en termostat som står i gangen som er ca 2,5 meter unna GW og termostaten på badet. Jeg regner med dette ikke er normalt, er det noen andre som har opplev dette problemet? Jeg regner med at dette er en reklamasjonssak? Ole Jacob
  11. Etter at garasjedøren gikk opp med et uhell mens jeg skiftet batteri på fjernkontrollen (ja, veldig teit av meg å ikke sjekke), så ble elsykkelen stjålet i løpet av natta. Så det er på tide å få fingeren ut og legge inn en bedre kontroll på garasjedøren. Jeg bruker Home Assistant og har lurt på å kjøpe Aeotec Garage Door Controller (https://aeotec.com/z-wave-garage-door-controller), siden det virker som at den både kan detektere vinkel på garasjeport og kontrollere motor. Men er det noen som har erfaringer med den, og hvordan å bruke den i HA?
  12. Jeg har kjøpt to multisensorer og føler jeg har hatt problemer siden første sekund. Det kan være jeg som gjør feil, men jeg håpte de virket ganske greit "out of the box". Først synes jeg begge to ser brukt ut. Linsen eller kuppelen foran ser noe slitt ut og den ene sensoren nede i hjørnet ser noe sideforskyvd ut. Da jeg skulle sette de opp slet jeg veldig med å koble den ene til min FH hub. Den dukket bare opp med batteriverdi, men etter 15-20 forsøk kom den inn med alle verdier. Det tok en halvtimes tid før alle verdiene oppdaterte seg, men de så ut til å virke greit begge to. Jeg satte de først på en hylle samme vei for å sjekke at de viste likt. Lux verdiene var ganske ulike på de og de oppdaterer seg veldig sjeldent selv om lyset forandrer seg ganske mye. Det går fort et par timer mellom hver oppdatering. I dag skulle jeg omsider henge opp den ene, men da vil den plutselig ikke registrere bevegelse. Dette har pleid å oppdatere seg i appen umiddelbart, men nå er det ingen reaksjon fra noen av de. Edit: Jeg dobbelsjekket mens jeg skrev teksten og da virker bevegelse greit. Jeg synes bare det er vanskelig å stole på når begge plutselig ikke var responsiv en stund sammen med alt det andre. Lux verdiene er også 600 og 1900 selv om de står på samme hylle og samme vei. Er det noe jeg gjør galt? Jeg vet folk her inne elsker disse sensorene, men jeg er ikke overbevist..
  13. Jeg har utvendige screens og har Aeotec Nano shutter (3stk, montert av elektriker) for styring av disse. Jeg har klart å legge til Nano shutter'ne i Home Assistant, men fjernstyringen virker ikke. Noen som har et fungerende oppsett og kan forklare hva jeg skal gjøre for å få dette til å fungere? Kan ikke se at det kommer noe i loggen når jeg trykker på veggbryter for å ta screen opp/ned. Jeg hører det klikke i nano shutter når jeg trykker på opp/ned i HA GUI, og følgende kommer i OZW_Log.txt: 2020-01-22 13:46:43.903 Info, Node031, Value::Set - COMMAND_CLASS_SWITCH_BINARY - Switch - 0 - 1 - True 2020-01-22 13:46:43.904 Info, Node031, SwitchBinary::Set - Setting node 31 to On 2020-01-22 13:46:43.904 Detail, Node031, Queuing (Send) SwitchBinaryCmd_Set (Node=31): 0x01, 0x0a, 0x00, 0x13, 0x1f, 0x03, 0x25, 0x01, 0xff, 0x25, 0x9b, 0x9f 2020-01-22 13:46:43.904 Detail, Node031, Queuing (Send) SwitchBinaryCmd_Get (Node=31): 0x01, 0x09, 0x00, 0x13, 0x1f, 0x02, 0x25, 0x02, 0x25, 0x9c, 0x66 2020-01-22 13:46:43.905 Detail, 2020-01-22 13:46:43.905 Info, Node031, Sending (Send) message (Callback ID=0x9b, Expected Reply=0x13) - SwitchBinaryCmd_Set (Node=31): 0x01, 0x0a, 0x00, 0x13, 0x1f, 0x03, 0x25, 0x01, 0xff, 0x25, 0x9b, 0x9f 2020-01-22 13:46:43.913 Detail, Node031, Received: 0x01, 0x04, 0x01, 0x13, 0x01, 0xe8 2020-01-22 13:46:43.913 Detail, Node031, ZW_SEND_DATA delivered to Z-Wave stack 2020-01-22 13:46:43.957 Detail, Node031, Received: 0x01, 0x07, 0x00, 0x13, 0x9b, 0x00, 0x00, 0x05, 0x75 2020-01-22 13:46:43.957 Detail, Node031, ZW_SEND_DATA Request with callback ID 0x9b received (expected 0x9b) 2020-01-22 13:46:43.957 Info, Node031, Request RTT 52 Average Request RTT 58 2020-01-22 13:46:43.957 Detail, Expected callbackId was received 2020-01-22 13:46:43.957 Detail, Expected reply was received 2020-01-22 13:46:43.957 Detail, Message transaction complete 2020-01-22 13:46:43.957 Detail, 2020-01-22 13:46:43.958 Detail, Node031, Removing current message 2020-01-22 13:46:43.958 Detail, 2020-01-22 13:46:43.958 Info, Node031, Sending (Send) message (Callback ID=0x9c, Expected Reply=0x04) - SwitchBinaryCmd_Get (Node=31): 0x01, 0x09, 0x00, 0x13, 0x1f, 0x02, 0x25, 0x02, 0x25, 0x9c, 0x66 2020-01-22 13:46:43.967 Detail, Node031, Received: 0x01, 0x04, 0x01, 0x13, 0x01, 0xe8 2020-01-22 13:46:43.967 Detail, Node031, ZW_SEND_DATA delivered to Z-Wave stack 2020-01-22 13:46:44.091 Detail, Node031, Received: 0x01, 0x07, 0x00, 0x13, 0x9c, 0x00, 0x00, 0x0d, 0x7a 2020-01-22 13:46:44.091 Detail, Node031, ZW_SEND_DATA Request with callback ID 0x9c received (expected 0x9c) 2020-01-22 13:46:44.091 Info, Node031, Request RTT 134 Average Request RTT 96 2020-01-22 13:46:44.091 Detail, Expected callbackId was received 2020-01-22 13:46:44.170 Detail, Node031, Received: 0x01, 0x09, 0x00, 0x04, 0x00, 0x1f, 0x03, 0x25, 0x03, 0xff, 0x37 2020-01-22 13:46:44.170 Detail, 2020-01-22 13:46:44.170 Info, Node031, Response RTT 213 Average Response RTT 208 2020-01-22 13:46:44.170 Info, Node031, Received SwitchBinary report from node 31: level=On 2020-01-22 13:46:44.170 Detail, Node031, Refreshed Value: old value=false, new value=true, type=bool 2020-01-22 13:46:44.171 Detail, Node031, Changes to this value are not verified 2020-01-22 13:46:44.171 Detail, Node031, Expected reply and command class was received 2020-01-22 13:46:44.171 Detail, Node031, Message transaction complete 2020-01-22 13:46:44.171 Detail, 2020-01-22 13:46:44.171 Detail, Node031, Removing current message 2020-01-22 13:46:44.171 Detail, Node031, Notification: ValueChanged 2020-01-22 13:46:44.230 Detail, Node031, Received: 0x01, 0x09, 0x00, 0x04, 0x00, 0x1f, 0x03, 0x25, 0x03, 0xff, 0x37 2020-01-22 13:46:44.230 Detail, 2020-01-22 13:46:44.230 Info, Node031, Received SwitchBinary report from node 31: level=On 2020-01-22 13:46:44.231 Detail, Node031, Refreshed Value: old value=true, new value=true, type=bool 2020-01-22 13:46:44.231 Detail, Node031, Changes to this value are not verified 2020-01-22 13:46:44.231 Detail, Node031, Notification: ValueChanged 2020-01-22 13:46:44.441 Detail, Node031, Received: 0x01, 0x09, 0x00, 0x04, 0x00, 0x1f, 0x03, 0x25, 0x03, 0xff, 0x37 2020-01-22 13:46:44.441 Detail, 2020-01-22 13:46:44.442 Info, Node031, Received SwitchBinary report from node 31: level=On 2020-01-22 13:46:44.442 Detail, Node031, Refreshed Value: old value=true, new value=true, type=bool 2020-01-22 13:46:44.442 Detail, Node031, Changes to this value are not verified 2020-01-22 13:46:44.442 Detail, Node031, Notification: ValueChanged
  14. Ville bare som relativt ny her takke alle som er aktive på forumet og bidrar både med plug-ins og gode løsninger. Spesielt takk til forfatter av Homeseer skolen som gir oss ferskinger en mulighet til å få til ting uten å rive av seg alt håret! For meg begynte det med opplegg av noen nye LED lys sløyfer i Stue gang og ute (SG armatur). Jeg tittet på løsninger for styring da jeg syntes at en app for bare styring av lys (SG sin blåtann dimmer) ikke var særlig nyskapende. Etter litt google søk havnet jeg på Homeseer og klinket til med pro til PC da det var Black Friday! Hittil har jeg 4 Ledlys sløyfer med Aeotec Nano dimmer. samt en go del veggplugger av både aeotec og Fibaro. DanalockV3 og Danapad. Varmekabler på inngangsparti har også fått styring via Aeotec heavy duty. Har en god del Aeotec multisensorer som står for tur til montering (gleder meg til å få styring via de). Verisure har blitt lagt inn på Homeseer (uten at jeg har kommet så mye lenger med det) Har også gått til innkjøp av en Logitech HUB som jeg håper å kunne legge styring av 2 varmepumper via (Panasonic). Jeg har rett å slett fått meg en ny hobby som startet med ett ønske om smart lysstyring på nye kurser. Veldig moro når det funker og frustrerende når jeg ikke får det til...
  15. Hei! Holder på å bygge en hytte som eg ønsker å gjøre smart/automatisert. Har ikke erfaring med hjemmeautomasjon fra før så eg prøver meg på et innlegg her. Visst det passer best en annen plass så må dere bare flytte innlegget. Utgangspunktet mitt er smart strømsparing via tibber, og et ønske om å ha kontroll på strømforbruket i hytta, ergo smart styring av hytta for å spare strøm. Etterkvart så ønsker eg utvide mulighetene, men har ikke tenkt ut alt enda.. Første prioritet er å tilrettelegge hytta i byggefasen for framtidige smarthus løsninger. Det er ønskelig at alle lys og varmestyring skal kunne håndteres både tradisjonelt(vanlige brytere / manuell inputt) og smart (ved bruk av app, stemmestyring etc). Har valgt å gå for en Futurehome løsning kombinert med produkter støttet av den løsningen. Valget er basert på at eg ønsker å støtte initiativet bak Tibber og Futurehome, samt at for mange valg gjør det vanskelig å ta et valg. Ønsker også at systemleverandøren håndtere testing av hvilke produkter som skal fungere i futurehome systemet i staden for at eg skal forske på det ? Vel det blei en lang intro. Spørsmålene mine er: Tenker å bruke FIBARO Single Switch 2 bak brytere for å styre lys på rom uten behov for dimming og Aeotec Nano Dimmer bak brytere for rom med behov for dimming. Då har eg forstått det slik at eg får mulighet til å få feedback på strøm forbruk, men det som er viktigast, eg får mulighet til å "smart" styre lysene. Valgte Aeotec Nano Dimmer fordi den håndtere LED lys bedre. Andre erfaringer som motsier det? Valgte Fibaro Switch fordi den var billigere en Aeotec sin. Hva er fordelen ved å bruke Fibaro Double switch. Er det visst du har feks har to brytere i en veggboks, styring av to lyssoner feks? Er det plass i en standard norsk Elko veggboks eller bør eg få elektriker til å montere bokser med ekstra plass? Har ønske om å måle strømforbruk på en del andre enheter også (Vaskemaskin, oppvaskmaskin, kjøleskap/frys, VVS) og lure på eg enten skal gå får Aeotec Smart Switch 6 (plug) eller om eg skal gå for skjult installasjon ved å bruke Aeotec Nano Switch. Kan evt bruke fibaro sin løsning men ser at dei håndtere lavere Watt effekt. Hva er deres erfaringer. Skjult installasjon eller plugg? Pris er nesten lik, men du må jo ha installatør visst du ønsker skjult installasjon. (monteringskost). Hvilke løsning er mest stabil? Mvh Morten
  16. Hei Jeg har noen Aeotec wallmote 4 og en del dimmere av forskjellig type - Fibaro dimmer 2, Qubino flush dimmer og noen Philips Hue-pærer. Wallmote-funksjonen for dimming (swipe opp/ned) fungerer dårlig, og er ikke tilgjengelig i Home Assistant. Jeg har begynt å lage en del i Node Red mot HA, og det ser veldig bra ut! Men det jeg ikke har fått til så langt er: Når jeg holder "inn" en knapp på wallmote, skal lyset stige med f.eks. 20% pr. sekund til det er på maks. Deretter tilbake til og starter oppover igjen. Noen ideer om hvordan jeg skal få til det? Helge
  17. Hei. Noen som vet en mulighet for og logge temperatur å kanskje få ut en graf. Bruker Aeotec Multisensor til å lese av temp gjennom Smartthings HUB. Mvh Peder
  18. Er det noen som har erfaring med Aeotec Multisensor 6 i Home Center Lite? Den blir kun registrert som temperatursensor, og den er helt av. Innimellom så hopper temperaturen rundt, eller så står den fast på over 60 og jeg blir spammet med advarsler om mulig brann. Noen som har erfaringer med kombinasjonen Aeotec Multisensor 6 og HCL? Hvordan får man opp bevegelsessensor, ikke bare temperatur i HCL? Hvor stiller man inn de forskjellige parametere man kan lese i manualen? De skal brukes til å styre lys via Fibaro Dimmer 2. Bruker relativt mye på å legge opp fast strøm til disse sensorene (elektriker har slisset seg fra sikringsskap gjennom vegg, ventilasjonssjakt og tak for å legge det skjult, på timehonorar på 960 kroner, og det er tydelig at han er elektriker og ikke tømrer ? ), så blir ganske fortvilet om det ikke blir en god løsning.
  19. Kjører hassio på Raspberry Pi og har installert garasjekontrolleren fra Aeotec (Aeotec Garage door controller). Enheten dukket opp med totalt fire "entities" (?) i kontrollpanelet (Access control, alarm level, alarm type og sorucenode). Er dette noe jeg har brukt for til noe? Jeg har vel egentlig bare behov for "Cover" og kan bruke den for å sjekke tilstander og kjøre opp og ned?
  20. T-Rex

    Problem Z-stick

    Hei jeg har nylig satt opp HS3 på linux etter å ha prøvd litt forskjellige systemer, men jeg sliter med z-wave kontrolleren. Det er en Aeotec z-stick gen 5. Den henger seg opp i tide og utide. Får da feilmelding i loggen: Z-stick: Cannot configure COM port /dev/ttyACM0, port does not exist in system, waiting then retrying... I tillegg slutter lyset på å blinke, i tillegg og viser ikke usb-porten lengre på kontrolleren. Noen som vet om dette er et kjent problem på z-sticken, Homeseer eller om jeg gjør noe feil? Setter stor pris på svar, for WAF synker kraftig hver gang det ikke virker
  21. Da var også jeg i gang! Hadde plutselig en pakke med Zee2, Aeotec Wallmote Quad bryter, og en Aeotec nano dimmer på døra. Men nå har jeg sittet i hele ettermiddag og kveld og prøvd å få lyset til å dimme. Blir så frustrert over å ikke finne ut av dette :-/ Det eneste jeg får til er å skru lyset av og på. Dette gjør jeg ved å gå inn i Wallmote noden, og f.eks "switch multilevel 2" og velge "linked device", hvor jeg videre velger aeotec nano noden og "switch multilevel". Om dette er rett eller galt aner jeg ikke, men av/på funker i alle fall. Men å dimme opp eller ned ved hjelp av sveipe/slide opp/ned funker ikke. Har prøvd å sette parameter 4 til "3" uten å lykkes. Noen tips? ?
  22. Jeg skaffet en Aeotec Multisensor 6 for å ha på badet. For å få bedre kontroll med lys og vifte der. Men: Jeg får den ikke til å sende når det er endringer i lys, temperatur eller luftfuktighet! Den sender bare på wakeup-tidspunktene, som jeg tror er hver time. Dette er når den går på batteri. Når den får strøm via USB ser det greit ut, men det er ikke noe alternativ. Den er litt kinkig å sette opp for temperaturparametre, men eller skulle man tro den var enkel. Har forsøkt å koble den fra/resette/koble til min Fibaro HC2 noen ganger uten at det hjelper. Noen som har erfaringer å dele?
  23. Aeotec Dør/Vindu sensor 6 En minimal Z-Wave Plus enhet fra Aeon Labs Den nye Aeotec Dør/Vindu Sensor 6 er en Z-Wave Plus sensor fra Aeon Labs som er utformet med et minimalt utseende, designet for å gli inn i ethvert hjem og enhver dekor. I tillegg dekkes den av et 9x72mm ABS plastetui som er utformet til å bli malt slik at du kan gi den en farge som passer inn med dine dører og vinduer. Gen5 enheten inneholder 2 magnetisk reed brytere langs kanten som benytter en slank magnet (2mm) som kan plasseres opptil 2.2cm unna. Både monteringsplate og magnet kan installeres ved bruk av enten dobbeltsidig tape, små skruer eller lim. Aeon Labs sier det innebygde 500mAh batteriet skal vare i over 1 år på vinduer og rundt 10 måneder på ofte brukte dører. Når batteriet er utladet, fjerner du sensoren fra sin monteringsplate og lader den i et par timer via USB. Andre egenskaper den inkluderer er advarsler om lavt batterinivå, over-the-air (OTA) firmwareoppdateringer, og en optimalisert rekkevidde på 150m punkt til punkt. Designet for å gli inn i ethvert hjem og enhver dekor. Aeotec Dør/Vindu Sensor 6 er konstruert for å gjøre hjemmet ditt smartere. Intelligens er det som gjør ditt tilkoblede hjem smart. Med en dør/vindu sensor vil ditt smarthus system ha informasjon om status på de viktigste dører og vinduer i hjemmet ditt. Det vil vite når de er åpne. Det vil vite når de er stengt. Du vet også når de har blitt åpnet og om de ikke burde være åpnet. Du kan bruke denne informasjonen til å slå på lys, aktivere videokamera, sende push melding osv. Sensor installert (nederst til høyre) ZW112-C Dør/Vindu sensor 6 er allerede tilgjengelig i norske nettbutikker for rundt 490 kroner.
  24. Hei Jeg har nylig gått i gang med Fibaro HC2 i huset mitt. Har satt opp fire rom med diverse Fibaro sensorer, innbyggingsdimmere, kontaktswitcher, lekkasjesensorer osv. Så kjøpte jeg meg en Aeotec Dimmer 6 for å kunne dimme en gulvstående lampe i stua. Når jeg legger til denne enheten så får jeg den opp i flere forskjellige versjoner i kontrollpanelet. Se bilde vedlagt. Dette blir rotete, men jeg klarer ikke å slette duplikatene. Skjønner ikke helt hvorfor de dukker opp slik. Noen tips? B.B.
  25. Hei, Jeg har montert et par multisensor 6 fra Aeotec i huset nå, men sliter med at de trigger på bikkja når vi ikke er hjemme. Jeg får masse pushmeldinger på mobilen om bevegelse mens vi er borte. Jeg kan jo endre parameter i multisensorene, men vil ikke sette de for lavt heller. Noen erfaringer? Jeg har også slitt litt med å parametrere tidsintervall for rapportering til Futurehome hub'en. Satt i desperasjon parameter 111,112, og 113 til 260 da jeg ikke er helt innforstått med de forskjellige "gruppene" i z-wave. I utgangspunktet er jeg litt keen på "sanntidsdata" da jeg har sensorene tilkoblet USB og slipper å tenke på batterier. Er dette mulig med denne? /Audun
  • Medlemsstatistikk

    6 972
    Totalt antall medlemmer
    1 891
    Flest pålogget
    molefonken
    Nyeste medlem
    molefonken
    Ble med
×
×
  • Opprett ny...

Viktig informasjon

Vi har plassert informasjonskapsler/cookies på din enhet for å gjøre denne siden bedre. Du kan justere dine innstillinger for informasjonskapsler, ellers vil vi anta at dette er ok for deg.